home *** CD-ROM | disk | FTP | other *** search
/ IRIX Base Documentation 2002 November / SGI IRIX Base Documentation 2002 November.iso / usr / share / catman / u_man / cat1 / pmcd_wait.z / pmcd_wait
Encoding:
Text File  |  2002-10-03  |  4.4 KB  |  133 lines

  1.  
  2.  
  3.  
  4. PPPPMMMMCCCCDDDD____WWWWAAAAIIIITTTT((((1111))))                                                      PPPPMMMMCCCCDDDD____WWWWAAAAIIIITTTT((((1111))))
  5.  
  6.  
  7.  
  8. NNNNAAAAMMMMEEEE
  9.      ppppmmmmccccdddd____wwwwaaaaiiiitttt - wait for PMCD to accept client connections
  10.  
  11. SSSSYYYYNNNNOOOOPPPPSSSSIIIISSSS
  12.      $$$$PPPPCCCCPPPP____BBBBIIIINNNNAAAADDDDMMMM____DDDDIIIIRRRR////ppppmmmmccccdddd____wwwwaaaaiiiitttt [----hhhh _h_o_s_t] [----tttt _i_n_t_e_r_v_a_l] [----vvvv]
  13.  
  14. DDDDEEEESSSSCCCCRRRRIIIIPPPPTTTTIIIIOOOONNNN
  15.      ppppmmmmccccdddd____wwwwaaaaiiiitttt waits for the Performance Metrics Collector Daemon (PMCD) to be
  16.      running and accepting client connections.
  17.  
  18.      Unless directed to another host by the ----hhhh option, ppppmmmmccccdddd____wwwwaaaaiiiitttt will try to
  19.      contact ppppmmmmccccdddd(1) on the local host.
  20.  
  21.      ppppmmmmccccdddd____wwwwaaaaiiiitttt will timeout and abandon the attempt to connect to ppppmmmmccccdddd after
  22.      60 seconds.  This default timeout interval may be changed using the ----tttt
  23.      option, where the _i_n_t_e_r_v_a_l argument follows the syntax described in
  24.      PPPPCCCCPPPPIIIInnnnttttrrrroooo(1) and in the simplest form may be an unsigned integer (the
  25.      implied units in this case are seconds).
  26.  
  27.      On successful connection to ppppmmmmccccdddd an exit status of zero is returned.
  28.  
  29.      If an error or timeout occurs, then a non-zero exit status is returned as
  30.      described below.
  31.  
  32.      The other options are as follows:
  33.  
  34.      ----vvvv   This option turns the verbose mode on.  With the verbose mode off
  35.           (which is the default), no output will be generated.  With verbose
  36.           mode on, error messages will be output on _s_t_d_e_r_r.
  37.  
  38. PPPPCCCCPPPP EEEENNNNVVVVIIIIRRRROOOONNNNMMMMEEEENNNNTTTT
  39.      Environment variables with the prefix PPPPCCCCPPPP____ are used to parameterize the
  40.      file and directory names used by PCP.  On each installation, the file
  41.      /_e_t_c/_p_c_p._c_o_n_f contains the local values for these variables.  The
  42.      $$$$PPPPCCCCPPPP____CCCCOOOONNNNFFFF variable may be used to specify an alternative configuration
  43.      file, as described in ppppccccpppp....ccccoooonnnnffff(4).
  44.  
  45. SSSSEEEEEEEE AAAALLLLSSSSOOOO
  46.      PPPPCCCCPPPPIIIInnnnttttrrrroooo(1), ppppmmmmccccdddd(1), ppppccccpppp....ccccoooonnnnffff(4) and ppppccccpppp....eeeennnnvvvv(4).
  47.  
  48. DDDDIIIIAAAAGGGGNNNNOOOOSSSSTTTTIIIICCCCSSSS
  49.      Error messages will be output to _s_t_d_e_r_r only if the verbose mode is on.
  50.  
  51.      The following exit status codes are returned:
  52.  
  53.      0000    ppppmmmmccccdddd____wwwwaaaaiiiitttt was able to successfully connect to ppppmmmmccccdddd within the
  54.           timeout period.
  55.  
  56.      1111    A usage error occurred, use ----vvvv for more details.
  57.  
  58.  
  59.  
  60.  
  61.  
  62.  
  63.                                                                         PPPPaaaaggggeeee 1111
  64.  
  65.  
  66.  
  67.  
  68.  
  69.  
  70. PPPPMMMMCCCCDDDD____WWWWAAAAIIIITTTT((((1111))))                                                      PPPPMMMMCCCCDDDD____WWWWAAAAIIIITTTT((((1111))))
  71.  
  72.  
  73.  
  74.      2222    No connection was made in the timeout interval.  This will happen if
  75.           ppppmmmmccccdddd is running but takes too long to complete the client
  76.           connection, or if ppppmmmmccccdddd is not running and all connection attempts in
  77.           the timeout interval failed with the error ECONNREFUSED.
  78.  
  79.      3333    A UNIX error occurred, use ----vvvv for more details.
  80.  
  81.      4444    A PCP error occurred, use ----vvvv for more details.
  82.  
  83.  
  84.  
  85.  
  86.  
  87.  
  88.  
  89.  
  90.  
  91.  
  92.  
  93.  
  94.  
  95.  
  96.  
  97.  
  98.  
  99.  
  100.  
  101.  
  102.  
  103.  
  104.  
  105.  
  106.  
  107.  
  108.  
  109.  
  110.  
  111.  
  112.  
  113.  
  114.  
  115.  
  116.  
  117.  
  118.  
  119.  
  120.  
  121.  
  122.  
  123.  
  124.  
  125.  
  126.  
  127.  
  128.  
  129.                                                                         PPPPaaaaggggeeee 2222
  130.  
  131.  
  132.  
  133.